Argox PA-20 Basic Programming Manual Manual do Utilizador Página 66

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 143
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 65
PT-Basic Programming Manual Ver. 1.00 65/143
ICON_ZONE_PRINT
Purpose
To enable or disable the status bar.
Syntax
ICON_ZONE_PRINT(status%)
Example
ICON_ZONE_PRINT(0)
Description
status% is an integer variable indicating the status bar is on
or off.
If using this command, all of the TextBlock setting will be
reset.
status%
Meaning
0
Status bar off
1
Status bar on
PRINT
Purpose
To display data in the activated TextBlock.
Syntax
PRINT expression[{,|;[expression]}]
Example
PRINT "Print data"
X% = CURSOR_X
Y% = CURSOR_Y
PRINT "Cur. Location=>(";X%;",";Y%;")"
Description
expression may be numeric or string expression.
The position of echo printed item is determined by the
punctuation used to separate items in the list. In the list of
expression, a comma causes the next character to be printed
after the last character with a blank space. A semicolon
causes the next character to be printed immediately after the
last character. If the list of expressions terminates without a
comma or semicolon, a carriage return is printed at the end of
the line.
CLR_RECT
Purpose
To clear a rectangular area in the activated TextBlock. The
cursor position is not affected after the operation.
Syntax
CLR_RECT(left% , top% , width% , height%)
Example
CLR_RECT(100,100,100,100)
Description
Several key argument as below:
left %
Fill from the start point of X-axis (pixel).
top %
Fill from the start point of Y-axis (pixel).
width%
Fill the width from the start point (pixel).
height%
Fill the height from the start point (pixel).